A comparative study on PCA and LDA based EMG pattern recognition for anthropomorphic robotic hand | |
Zhang DH(张道辉); Zhao XG(赵新刚); Han JD(韩建达); Zhao YW(赵忆文) | |
2014 | |
会议名称 | 2014 IEEE International Conference on Robotics and Automation (ICRA 2014) |
会议日期 | May 31 - June 7, 2014 |
会议地点 | HongKong, China |
页码 | 4850-4655 |
通讯作者 | 张道辉 |
中文摘要 | A multifunctional myoelectric prosthetic hand is a perfect gift for an upper-limb amputee, however, the myoelectric control for a prosthetic hand is not so good now. Here, the paper presents a comparative study on electromyography (EMG) pattern recognition based on PCA and LDA for an anthropomorphic robotic hand. Four channels of surface EMG (sEMG) signals were recorded from the subject’s forearm. Time-domain analysis, frequency-domain analysis, wavelet transform analysis, nonlinear entropy analysis and fractal analysis were done and fourteen kinds of features were extracted from sEMG signals. The features were divided into four groups, and the performances of the four groups were compared and analyzed. In the feature projection stage, three schemes were proposed and their performances were compared with each other. The first one only used the principal component analysis (PCA) for dimension reduction. And the second one only used the linear discriminant analysis (LDA) for dimension reduction. The third one used PCA for the first step of dimensionality reduction, and then used LDA for the next step of dimensionality reduction. In the classification stage, minimum distance classifier (MDC) was employed for identifying nine kinds of hand/wrist motions in the projected space. Comparative experiments of four groups of features and three projection schemes were done and evaluated. The online experiment of real-time myoelectric control for an anthropomorphic robotic hand was done as well. |
收录类别 | EI ; CPCI(ISTP) |
产权排序 | 1 |
会议录 | 2014 IEEE International Conference on Robotics and Automation (ICRA 2014) |
会议录出版者 | IEEE |
会议录出版地 | Piscataway, NJ, USA |
语种 | 英语 |
ISBN号 | 978-1-4799-3685-4 |
WOS记录号 | WOS:000377221104134 |
内容类型 | 会议论文 |
源URL | [http://ir.sia.cn/handle/173321/15395] |
专题 | 沈阳自动化研究所_机器人学研究室 |
推荐引用方式 GB/T 7714 | Zhang DH,Zhao XG,Han JD,et al. A comparative study on PCA and LDA based EMG pattern recognition for anthropomorphic robotic hand[C]. 见:2014 IEEE International Conference on Robotics and Automation (ICRA 2014). HongKong, China. May 31 - June 7, 2014. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论