CORC

浏览/检索结果: 共10条,第1-10条 帮助

限定条件                    
已选(0)清除 条数/页:   排序方式:
Detection and analysis of 1/f noise correlation in semiconductor laser diodes 会议论文
7th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, AOMATT 2014, April 26, 2014 - April 29, 2014, Harbin, China
Fan H.-J.; Gao F.-L.; Cao J.-S.; Guo S.-X.
收藏  |  浏览/下载:12/0  |  提交时间:2015/04/27
Power spectral density specification and analysis of system optical jitter 会议论文
International Symposium on Optoelectronic Technology and Application 2014: Imaging Spectroscopy; and Telescopes and Large Optics, IPTA 2014, May 13, 2014 - May 15, 2014, Beijing, China
An Q.-C.; Yang F.; Guo P.; Liu X.-Y.
收藏  |  浏览/下载:11/0  |  提交时间:2015/04/27
Noise analysis and filtering for laser active imaging system 会议论文
2013 2nd International Conference on Sensors, Measurement and lntelligent Materials, ICSMIM 2013, November 16, 2013 - November 17, 2013, Guangzhou, China
Tao S.
收藏  |  浏览/下载:18/0  |  提交时间:2015/04/27
The research of multi-frame target recognition based on laser active imaging 会议论文
5th International Symposium on Photoelectronic Detection and Imaging, ISPDI 2013, June 25, 2013 - June 27, 2013, Beijing, China, June 25, 2013 - June 27, 2013
Wang C.-J.; Sun T.; Wang T.-F.; Chen J.
收藏  |  浏览/下载:9/0  |  提交时间:2014/05/15
Field-line coupling interference prediction of LCD module in high-power TEA CO2 laser system (EI CONFERENCE) 会议论文
2012 International Conference on Optoelectronics and Microelectronics, ICOM 2012, August 23, 2012 - August 25, 2012, Changchun, China
Ge X.; Li X.
收藏  |  浏览/下载:13/0  |  提交时间:2013/03/25
Autocollimation form dual-frequency laser diffraction grating interferometer design and analysis (EI CONFERENCE) 会议论文
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Wang C.-G.
收藏  |  浏览/下载:19/0  |  提交时间:2013/03/25
Propose a new measurement system of autocollimation form laser grating heterodyne interferometer. Take grating diffraction and polarization optics as theoretical foundation  second  furthermore  combined with electronics knowledge to analyze the system. First  make use of autocollimation diffraction of grating  measurement information obtained by dual-frequency laser belongs to ac signal  the interferometer measurement system take grating pitch as measuring datum  the structure is simple  possess great gain and high signal-noise ratio  therefore  stable  completely overcome the disadvantages of DC level drift caused by light intensity variation of single-frequency laser  system can achieve nanometer resolution. 2010 IEEE.  reduce the impact of environmental factors  easy to install and debug  measurement error is small  
A sensitive solid-phase time-resolved fluorescence immunoassay apparatus (EI CONFERENCE) 会议论文
International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging, June 17, 2009 - June 19, 2009, Beijing, China
Wang Y.-L.; Song K.-F.; Zhang W.-L.; Li J.-L.
收藏  |  浏览/下载:24/0  |  提交时间:2013/03/25
In the device  a He-Ne laser of flash frequency 1-20 Hz was adopted as exciting light source  and three key technical problems have been solved successfully in order to enhance the detecting sensitivity and measuring stability of the device for time-resolved fluorimmunoassays(TRFIA) [1]. The first one is to design optimum exciting optical system  so that the exciting light beam excite the sample most effectively. The second one is to have a project spectrum filter which can reduce the affection of the background light to the photomultiplier tube and also ensure influence of the stray light and mixed diffusion light to the sample fluorescence to the least  the sample fluorescence through the integrating sphere and come to the grating monochromator  The right wavelength will be chosed through changing the angle of incidence of the grating monochromator. The third one is to simulate the principle of sample averaging of BOXCAR averager. In the device  SCM was used as primary controller and CPLD was used as timing controller. Through the preparation process  signal-to-noise ratio(SNR) will be improved  also adjust delay time  ampling frequency and sampling number arbitrarily. By testing  the sensitivity is 10-12mol/L(substance marked by Eu3+)  examination repeat is &le2.5%  examination linearity is from 10 -8mol/L to 10-12mol/L  correlation coefficient is 99.98%(p&le0.01). The instrument is advanced for ultrasensitive detection of antigen and antibody  and solve the tumor  genetic variation  the virus protein detection. 2009 SPIE.  
Noise characteristic of laser diode pumped orange-yellow solid-state laser by intracavity sum-frequency of KTP Phase matching II (EI CONFERENCE) 会议论文
ICO20: Lasers and Laser Technologies, August 21, 2005 - August 26, 2005, Changchun, China
Tan H.; Gao L.
收藏  |  浏览/下载:13/0  |  提交时间:2013/03/25
Noise characteristic of laser diode pumped orange-yellow solid-state laser by intracavity sum-frequency of KTP phase matching II - art. no. 602817 会议论文
2005
Tan H. M.; Gao L. L.
收藏  |  浏览/下载:6/0  |  提交时间:2013/03/28
All-solid-stated laser controller design based on digital optical feedback (EI CONFERENCE) 会议论文
Lasers in Material Processing and Manufacturing II, November 10, 2004 - November 12, 2004, Beijing, China
Liu L.; Wang J.-L.; Zhou C.-Y.; Ge W.-Q.
收藏  |  浏览/下载:23/0  |  提交时间:2013/03/25
The new design about a CW  digital all-solid-stated LD pumped Nd:YVO 4 controller is introduced. The stable output power of this digital laser controller which adopts Digital Signal Processor(TMS320C31) is approximately 20mW. The whole system is composed of constant- current source  protection circuit  pulse-width modulation circuit  Si-photo-detector and amplified circuit and Digital Signal Processor control system  etc. In terms of error deviation Based on nonlinear control curves of LD power output by Si-photo-detector  the region control can be obtained by means of the PID control algorithm in the software platform  that is  error amendment and high stability laser power output can be achieved. And the precision of temperature control can reduce from 0.2C to 0.04C. By adopted integral separated mode PID control algorithm  the LD output power instability ( %) down to 2%. By way of adopting the new digital design  the work to protect the laser diode  including the continuous adjustable output power with high accuracy and stability  is easily obtained. The internal-external modulation control of the laser power based on digital optical feedback can be accomplished with stable power output. At last  the bringing reasons of noise are analyzed and the solving methods are put forward in this paper.  


©版权所有 ©2017 CSpace - Powered by CSpace