The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels | |
Gao, Caixia1,2; Jiang, Xiaoguang1,2; Li, Xianbin3; Li, Xiaohui1 | |
刊名 | INTERNATIONAL JOURNAL OF REMOTE SENSING
![]() |
2013-05-01 | |
卷号 | 34期号:9-10页码:3688-3698 |
英文摘要 | Radiometric calibration is a prerequisite to quantitative remote sensing, and its accuracy has a direct impact on the reliability and accuracy of the quantitative application of remote-sensing data. This article attempts to cross-calibrate the visible and near-infrared channels 1 (450-520 nm), 2 (520-590 nm), 3 (630-690 nm), and 4 (770-890 nm) of the China-Brazil Earth Resources Satellite (CBERS)-02B/charge-coupled device (CCD) camera with channels 3 (459-479 nm), 4 (545-565 nm), 1 (620-670 nm), and 2 (841-876 nm) of the Terra/Moderate Resolution Imaging Spectroradiometer (MODIS), respectively. The radiative transfer modelling (RTM) method is implemented using the CBERS-02B/CCD and Terra/MODIS measurements at the Dunhuang radiometric calibration site in October 2008. The differences between the cross-calibration and vicarious calibration techniques for channels 1, 2, 3, and 4 are 11.15%, -0.89%, 2.88%, and 11.28%, respectively. Furthermore, the accuracies of the cross-calibration coefficients of CBERS-02B/CCD are analysed, wherein the results indicate that the calibration uncertainty is within 5%. |
WOS标题词 | Science & Technology ; Technology |
类目[WOS] | Remote Sensing ; Imaging Science & Photographic Technology |
研究领域[WOS] | Remote Sensing ; Imaging Science & Photographic Technology |
关键词[WOS] | ABSOLUTE CALIBRATION ; SATELLITE SENSORS ; TERRA-MODIS ; IN-FLIGHT ; REFLECTANCE ; TARGETS |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000330301700020 |
公开日期 | 2015-12-24 |
内容类型 | 期刊论文 |
源URL | [http://ir.ioe.ac.cn/handle/181551/1241] ![]() |
专题 | 光电技术研究所_光电技术研究所被WoS收录文章 |
作者单位 | 1.Chinese Acad Sci, Acad Optoelect, Beijing 100190, Peoples R China 2.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China 3.Chinese Acad Sci, Inst Opt & Elect, Chengdu 610209, Peoples R China |
推荐引用方式 GB/T 7714 | Gao, Caixia,Jiang, Xiaoguang,Li, Xianbin,et al. The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels[J]. INTERNATIONAL JOURNAL OF REMOTE SENSING,2013,34(9-10):3688-3698. |
APA | Gao, Caixia,Jiang, Xiaoguang,Li, Xianbin,&Li, Xiaohui.(2013).The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels.INTERNATIONAL JOURNAL OF REMOTE SENSING,34(9-10),3688-3698. |
MLA | Gao, Caixia,et al."The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels".INTERNATIONAL JOURNAL OF REMOTE SENSING 34.9-10(2013):3688-3698. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论