Fluorescence X-ray source used for calibrating the detector of X-ray navigation
Dai Jin-Fei1,2; Zhao Bao-Sheng1; Sheng Li-Zhi1; Zhou Yan-Nan1; Chen Chen1; Song Juan1,2; Liu Yong-An1; Li Lin-Sen1,2
刊名acta physica sinica
2015-07-20
卷号64期号:14页码:426-431
关键词X-ray pulsar navigation fluorescence X-ray source detector calibration
其他题名标定脉冲星导航探测器的荧光x射线光源
英文摘要lots of research work on the x-ray pulsar navigation detector has been carried out, but the rigorous quantitative calibration results of these detectors have never been given out. in order to further promote the research process in x-ray pulsar navigation field, a kind of high-precision x-ray source which could be tunable in energy distribution and photon flux is necessary. a new method has been proposed to generate such an x-ray source, in which a conventional x-ray tube which is called the original level tube is used to excite a special fluorescence target to generate fluorescence x-ray source. firstly, the primary experiment system is built, with which the intensity of the fluorescence x-ray source is measured in atmospheric environment. the result indicates that the fluorescence x-ray source can be implemented in vacuum system to calibrate the detectors. then an integral fluorescence x-ray source is fabricated which can be used in vacuum system and its intensity is measured under the condition of d-x = 300 cm and i-a = 200 mu a. the photo fluxes are obtained to be 19.57 phs/s at 4.51 kev, 25.22 phs/s at 5.41 kev, and 33.27 phs/s at 8.05 kev. these data demonstrate the correctness of our method and that this new fluorescence x-ray source can be used to calibrate the x-ray pulsar navigation detector.
WOS标题词science & technology ; physical sciences
类目[WOS]physics, multidisciplinary
研究领域[WOS]physics
收录类别SCI ; EI
语种中文
WOS记录号WOS:000362976400055
公开日期2015-12-01
内容类型期刊论文
源URL[http://ir.opt.ac.cn/handle/181661/25500]  
专题西安光学精密机械研究所_光电子学研究室
作者单位1.Chinese Acad Sci, Xian Inst Opt & Precis Mech, State Key Lab Transent Opt & Photon, Xian 710119, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100084, Peoples R China
推荐引用方式
GB/T 7714
Dai Jin-Fei,Zhao Bao-Sheng,Sheng Li-Zhi,et al. Fluorescence X-ray source used for calibrating the detector of X-ray navigation[J]. acta physica sinica,2015,64(14):426-431.
APA Dai Jin-Fei.,Zhao Bao-Sheng.,Sheng Li-Zhi.,Zhou Yan-Nan.,Chen Chen.,...&Li Lin-Sen.(2015).Fluorescence X-ray source used for calibrating the detector of X-ray navigation.acta physica sinica,64(14),426-431.
MLA Dai Jin-Fei,et al."Fluorescence X-ray source used for calibrating the detector of X-ray navigation".acta physica sinica 64.14(2015):426-431.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace