FY-3B卫星微波湿度计热真空定标方法和结果分析
王振占 ; 张升伟 ; 李靖
刊名中国工程科学
2013
卷号15期号:10页码:33-46
关键词风云三号卫星 微波湿度计 发射前定标 热真空定标
ISSN号1009-1742
其他题名Thermal/vacuum calibration of microwave humidity sounder on FY-3B satellite
通讯作者北京8701信箱
中文摘要本文论述了风云三号卫星B星微波湿度计(MWHS-3B)发射前热真空定标的原理和方法,建立了各种定标误差的修正算法,获得了MWHS-3B的系统线性度、观测不同目标的灵敏度和最终定标精度等关键技术指标。这些参数已经用于MWHS-3B在轨数据的处理。
英文摘要The principle and methods on thermal/vacuum (T/V) testing of microwave humidity sounder (MWHS) on FY-3B satellite were described; correction algorithms on calibration errors were developed, and some main specifications of MWHS-3B, such as linearity, sensitivity and calibration precision, were obtained. The parameters derived from the T/V testing had been used in in-orbit data processing to produce brightness temperature products in FY-3B ground system.
学科主题微波遥感
语种中文
内容类型期刊论文
源URL[http://ir.cssar.ac.cn/handle/122/2084]  
专题国家空间科学中心_微波遥感部
推荐引用方式
GB/T 7714
王振占,张升伟,李靖. FY-3B卫星微波湿度计热真空定标方法和结果分析[J]. 中国工程科学,2013,15(10):33-46.
APA 王振占,张升伟,&李靖.(2013).FY-3B卫星微波湿度计热真空定标方法和结果分析.中国工程科学,15(10),33-46.
MLA 王振占,et al."FY-3B卫星微波湿度计热真空定标方法和结果分析".中国工程科学 15.10(2013):33-46.