Simultaneous measurement of NO and NO2 by dual-channel cavity photoacoustic spectroscopy technique
Jin, Hua-wei2,3,4; Fang, Lei2; Li, Zhi-yan1,4; Wang, Dan1,4
刊名OPTICS AND LASER TECHNOLOGY
2022-12-01
卷号156
关键词NOx PAS Dual-channel cavity Simultaneous measurement CRDS
ISSN号0030-3992
DOI10.1016/j.optlastec.2022.108589
通讯作者Jin, Hua-wei(hwjin@mail.ustc.edu.cn)
英文摘要The levels of nitric oxide (NO) and nitrogen oxide (NO2) are trace gases in the order of ppb, which are the main products of fossil fuel, anthropogenic combustion, natural lightning and microbial emissions, and are important for further analysis of air quality. Photoacoustic spectroscopy (PAS) technique, which is based on absorption at the wavelength of 403.65 nm, has been used for NO2 measurements. In this study, a dual-channel PAS system for NO2 and NOx detection is reported. The PAS method is capable of measuring species with good sensitivity and accuracy. The calibrated slopes of photoacoustic cavity A and B are 0.040 mu v/ppb and 0.039 mu v/ppb, respectively. And the detection limits of the developed PAS system for NO2 and NOx measurements are estimated to be about 1.47 ppb (30, 60 s) and 1.50 ppb (30, 60 s), respectively. In order to reduce the influence of local noise, the photoacoustic cavity with multiple buffer partitions is designed and the corresponding photoacoustic frequency of the photoacoustic pool is analyzed. The sound pressure value and resonance frequency of the photoacoustic pool gradually decrease with the increase of the number of buffer partitions, but the amplitude is small. The relationship between the gas absorption cross section, volume fraction, laser power and photoacoustic excitation signal is derived. After deducting the influence of local noise, the photoacoustic response gradients of dual -channel cavities are obtained, the linear fitting of the response gradient of both cavities is good, the correlation R2 is greater than 0.99, and the fitting slope is 0.040 and 0.039 respectively. The influence of O3 generated by photolysis of the mercury lamp is considered under different NO level conditions. An intercomparison be-tween the system and a cavity ring-down system (CRDS) independently developed by our research group showed a good agreement for measuring the ambient atmosphere NO2 gas. The results of NO2 showed a linear correction factor (R2) of 0.943 in a slope of 0.944 +/- 0.002, with an offset of (0.636 & PLUSMN; 0.021) ppb. The accuracy of NO2 measurement by the photoacoustic spectroscopy system was verified. In addition, the simultaneous measurement of NO and NO2 by dual-channel cavity photoacoustic spectroscopy technique was deployed. These observations indicate that NO2 and NO concentrations can be effectively observed with the dual-channel PAS instrument.
资助项目Major Project of Natural Science Research in Universities of Anhui Province[KJ2021ZD0052] ; Research and Development Project of Wuhu Research Institute of Anhui University of Science and Technology[ALW2020YF17] ; Natural Science Foundation of Anhui Province[2008085QD182] ; National Foundation of China[41905130]
WOS关键词NITRIC-OXIDE ; NITROGEN-DIOXIDE ; SENSOR ; CHEMILUMINESCENCE ; AMBIENT ; FLUORESCENCE ; TEMPERATURE ; INSTRUMENT ; SO2 ; O-3
WOS研究方向Optics ; Physics
语种英语
出版者ELSEVIER SCI LTD
WOS记录号WOS:000860742500007
资助机构Major Project of Natural Science Research in Universities of Anhui Province ; Research and Development Project of Wuhu Research Institute of Anhui University of Science and Technology ; Natural Science Foundation of Anhui Province ; National Foundation of China
内容类型期刊论文
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/129103]  
专题中国科学院合肥物质科学研究院
通讯作者Jin, Hua-wei
作者单位1.Anhui Univ Technol, Sch Math & Phys, Dept Optoelect Engn, Maan Shan 243032, Peoples R China
2.Anhui Univ Sci & Technol, State Key Lab Min Response & Disaster Prevent & Co, Huainan 232001, Peoples R China
3.Anhui Univ Sci & Technol, Inst Environm Friendly Mat & Occupat Hlth, Wuhu 241000, Peoples R China
4.Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Environm Opt & Technol, Hefei 230031, Peoples R China
推荐引用方式
GB/T 7714
Jin, Hua-wei,Fang, Lei,Li, Zhi-yan,et al. Simultaneous measurement of NO and NO2 by dual-channel cavity photoacoustic spectroscopy technique[J]. OPTICS AND LASER TECHNOLOGY,2022,156.
APA Jin, Hua-wei,Fang, Lei,Li, Zhi-yan,&Wang, Dan.(2022).Simultaneous measurement of NO and NO2 by dual-channel cavity photoacoustic spectroscopy technique.OPTICS AND LASER TECHNOLOGY,156.
MLA Jin, Hua-wei,et al."Simultaneous measurement of NO and NO2 by dual-channel cavity photoacoustic spectroscopy technique".OPTICS AND LASER TECHNOLOGY 156(2022).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace