Comparative analysis of vertical load bearing capacity of different serial seismic isolation system | |
Du, Yongfeng1,2; Han, Deng2 | |
刊名 | Tumu Gongcheng Xuebao/China Civil Engineering Journal |
2010-11-01 | |
卷号 | 43期号:SUPPL. 1页码:249-254 |
关键词 | ABAQUS Bearing capacity Bearings (structural) Buildings Computer simulation Finite element method Laminating Nonmetallic bearings Numerical methods Rubber Seismology Software testing Stiffness Comparative analysis Horizontal loading Independent columns Laminated rubber bearings Monotonic loading Seismic isolation Seismic isolation systems Vertical loadings |
ISSN号 | 1000131X |
英文摘要 | Taking the serial seismic isolation system, which consists of laminated rubber bearing mounted on top of basement column, as the investigated subject, the vertical load bearing capacity of serial isolation system with independent column are compared with that of the serial isolation system with link beam on top of basement column. 1 FEM model of serial isolation system with independent column and 3 models of serial isolation system with link beam of different beam-column linear stiffness ratios are established using nonlinear FEM Software ABAQUS, and a monotonic loading test of the serial isolation system is numerically simulated combined with horizontal loading of different initial values. The vertical-horizontal loading curve of serial isolation system are quantitatively compared for different initial values of horizontal load and different values of beam-column linear stiffness ratios, and the effect of these two factors on the ultimate vertical loading and on the damage pattern of serial isolation system are investigated. The result shows that the increase of vertical load bearing capacity of serial isolation system is directly proportional to beam-column linear stiffness ratios, and is inversely proportional to initial value of horizontal load. However, the relative degree of increase of vertical load bearing capacity is roughly proportional to initial value of horizontal load. However, the relative degree of increase of vertical load bearing capacity is roughly proportional to initial value of horizontal load. |
语种 | 中文 |
出版者 | Editorial Office of China Civil Engineering Journal |
内容类型 | 期刊论文 |
源URL | [http://ir.lut.edu.cn/handle/2XXMBERH/111463] |
专题 | 土木工程学院 |
作者单位 | 1.Western Center of Disaster Mitigation in Civil Engineering of Ministry of Education, Lanzhou University of Technology, Lanzhou 730050, China; 2.Institute of Earthquake Protection and Disaster Mitigation, Lanzhou University of Technology, Lanzhou 730050, China |
推荐引用方式 GB/T 7714 | Du, Yongfeng,Han, Deng. Comparative analysis of vertical load bearing capacity of different serial seismic isolation system[J]. Tumu Gongcheng Xuebao/China Civil Engineering Journal,2010,43(SUPPL. 1):249-254. |
APA | Du, Yongfeng,&Han, Deng.(2010).Comparative analysis of vertical load bearing capacity of different serial seismic isolation system.Tumu Gongcheng Xuebao/China Civil Engineering Journal,43(SUPPL. 1),249-254. |
MLA | Du, Yongfeng,et al."Comparative analysis of vertical load bearing capacity of different serial seismic isolation system".Tumu Gongcheng Xuebao/China Civil Engineering Journal 43.SUPPL. 1(2010):249-254. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论