A study of air-lift pump for circulating of refrigerant in shallow geothermal collecting system | |
Peng, Guoyi2; Suzuki, Takuma2; Oguma, Yasuyuki2; Quan, Hui1,2 | |
2020 | |
会议日期 | October 21, 2019 - October 25, 2019 |
会议地点 | Kunming, China |
关键词 | Air conditioning Compressed air Electric power utilization Heating Pumps Refrigerants Wind power Air-lift pumps Collecting systems Collection systems Energy supplies Liquid flow rates Pressurized air Renewable energies Solar and winds |
页码 | 436-439 |
英文摘要 | In recent years utilization of renewable energy attracts much attention from various viewpoints. However, renewable energies such as solar and wind are dependent upon climate and the stability of energy supply is a difficult matter. In contract, underground geothermal has a great advantage in stability although its developing cost is still high. Thus, utilization of relatively low-cost shallow geothermal, which is usually referred to the ground heat resource to the depth of several ten meters, has been concerned considerably and some illustrative cases such as air-conditioning of houses are reported. In such a shallow geothermal collecting system the pump used to circulate refrigerant solution occupies the most of power consumptions. Therefore, a combined utilization of renewable energies is contrived for reducing power consumptions of shallow geothermal collection system and an air-lift pump using pressurized air generated by solar and wind powers is developed at first. The liquid flow rate of the pump reaches to 12 L/min under the given condition and is larger than 8 L/min when the air flow rate is increased to 12.0 L/min while the submerged depth of air injector is over 5.0 ~10 m. The applicability of the air-lift pump to the extra-shallow geothermal collecting system adopted in the illustrative house of LOHAS established in Nihon University is confirmed. © ICOPE 2019 - 7th International Conference on Power Engineering, Proceedings. All rights reserved. |
会议录 | ICOPE 2019 - 7th International Conference on Power Engineering, Proceedings |
会议录出版者 | International Conference on Power Engineering-2019 |
语种 | 英语 |
内容类型 | 会议论文 |
源URL | [http://ir.lut.edu.cn/handle/2XXMBERH/118187] |
专题 | 能源与动力工程学院 |
作者单位 | 1.College of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou; 730050, China 2.College of Engineering, Nihon University, Koriyama; 963-8642, Japan; |
推荐引用方式 GB/T 7714 | Peng, Guoyi,Suzuki, Takuma,Oguma, Yasuyuki,et al. A study of air-lift pump for circulating of refrigerant in shallow geothermal collecting system[C]. 见:. Kunming, China. October 21, 2019 - October 25, 2019. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。