Ultrasensitive Optical Refractive Index Detection of NaCl and Alcohol Solutions Based on Weak Value Amplification
Xu, Liping2,4; Luo, Lan3; Wu, Hao1,4; Luo, Zhengchun2; Chang, Tianying2; Wu, Peng4; Du, Chunlei4; Cui, Hong-Liang2,4
刊名PLASMONICS
2019-12-04
页码8
关键词Ultrasensitive index change detection Weak value amplification Surface Plasmon resonance
ISSN号1557-1955
DOI10.1007/s11468-019-01037-1
通讯作者Chang, Tianying(tchang@jlu.edu.cn) ; Wu, Peng(pengwu@cigit.ac.cn)
英文摘要An ultrasensitive surface plasmon resonance (SPR) refractive index detection scheme based on weak value amplification is presented. Extremely low refractive index change (9.8 x 10(-7) RIU) of sodium chloride solution was readily measurable, with a resolution of 1.3 x 10(-7) RIU, a nearly three orders of magnitude increase in sensitivity over conventional SPR index-sensors via intensity interrogation. Preliminary measurement of refractive index change of alcohol solution demonstrated a minimum of 4.0 x 10(-6) RIU with a resolution of 3.7 x 10(-7) RIU, better than those obtained through wavelength-modulated heterodyne interferometry (with a resolution of 1.5 x 10(-6) RIU). The system is highly stable, having a simple and compact configuration, lending to easy and repeatable operation in standard ambient environment.
资助项目National Natural Science Foundation of China[61875196] ; State Oceanic Administration of China[201405026-01]
WOS研究方向Chemistry ; Science & Technology - Other Topics ; Materials Science
语种英语
出版者SPRINGER
WOS记录号WOS:000501352600001
内容类型期刊论文
源URL[http://119.78.100.138/handle/2HOD01W0/9996]  
专题中国科学院重庆绿色智能技术研究院
通讯作者Chang, Tianying; Wu, Peng
作者单位1.Harbin Inst Technol, Dept Phys, Harbin 150001, Heilongjiang, Peoples R China
2.Jilin Univ, Coll Instrumentat & Elect Engn, Changchun 130012, Jilin, Peoples R China
3.Sichuan Univ, Coll Phys Sci & Technol, Chengdu 610064, Sichuan, Peoples R China
4.Chinese Acad Sci, Chongqing Inst Green & Intelligent Technol, Chongqing 400714, Peoples R China
推荐引用方式
GB/T 7714
Xu, Liping,Luo, Lan,Wu, Hao,et al. Ultrasensitive Optical Refractive Index Detection of NaCl and Alcohol Solutions Based on Weak Value Amplification[J]. PLASMONICS,2019:8.
APA Xu, Liping.,Luo, Lan.,Wu, Hao.,Luo, Zhengchun.,Chang, Tianying.,...&Cui, Hong-Liang.(2019).Ultrasensitive Optical Refractive Index Detection of NaCl and Alcohol Solutions Based on Weak Value Amplification.PLASMONICS,8.
MLA Xu, Liping,et al."Ultrasensitive Optical Refractive Index Detection of NaCl and Alcohol Solutions Based on Weak Value Amplification".PLASMONICS (2019):8.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace