Matrix Measurement of Glucose Concentration Based on Surface Plasmon Resonance Sensor | |
Luo Wei1,3; Sun Feng-long1,3; Liu Jia-rui2; Hou Jun-wu1,3; Wang Ben-gan1,3; Huang Xiao-ping1,3 | |
刊名 | SPECTROSCOPY AND SPECTRAL ANALYSIS |
2018-06-01 | |
卷号 | 38期号:6页码:1982-1986 |
关键词 | Temperature RI Matrix measurement Parallel light path Surface Plasmon Resonance |
ISSN号 | 1000-0593 |
DOI | 10.3964/j.issn.1000-0593(2018)06-1982-05 |
英文摘要 | An angle scanning prism-based SPR sensor system is proposed in this paper. With the structure of reflex parallel light path, the system has been simplified, which mainly consists of light source, CCD sensor, parallel light path structure, rotation and temperature control module. With the motor scanning incidence angle and temperature control, an effective measurement of glucose refractive index (RI) mass concentration property can be achieved. Moreover, a theoretical model has been established to explain the existence of a sensitivity matrix, which enables both the RI and temperature to be measured and obtained from proof-of-concept experiment. This approach paves a way for conventional SPR-based sensors to discriminate between RI-induced and temperature-induced SPR changes and provides a reference for the correction of temperature interference. |
资助项目 | Natural Science Key Foundation, Department of Education, Anhui Province[KJ2016A305] ; National Science and Technology Support Program[2014BAD08B11] |
WOS关键词 | DNA |
WOS研究方向 | Spectroscopy |
语种 | 英语 |
出版者 | OFFICE SPECTROSCOPY & SPECTRAL ANALYSIS |
WOS记录号 | WOS:000435531000057 |
内容类型 | 期刊论文 |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/38359] |
专题 | 合肥物质科学研究院_中科院合肥智能机械研究所 |
通讯作者 | Luo Wei |
作者单位 | 1.Chinese Acad Sci, Inst Intelligent Machines, Hefei 230031, Anhui, Peoples R China 2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China 3.Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China |
推荐引用方式 GB/T 7714 | Luo Wei,Sun Feng-long,Liu Jia-rui,et al. Matrix Measurement of Glucose Concentration Based on Surface Plasmon Resonance Sensor[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2018,38(6):1982-1986. |
APA | Luo Wei,Sun Feng-long,Liu Jia-rui,Hou Jun-wu,Wang Ben-gan,&Huang Xiao-ping.(2018).Matrix Measurement of Glucose Concentration Based on Surface Plasmon Resonance Sensor.SPECTROSCOPY AND SPECTRAL ANALYSIS,38(6),1982-1986. |
MLA | Luo Wei,et al."Matrix Measurement of Glucose Concentration Based on Surface Plasmon Resonance Sensor".SPECTROSCOPY AND SPECTRAL ANALYSIS 38.6(2018):1982-1986. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论