英文摘要 | This paper covers the application of the cross-correlation method for measuring the velocity of solid particles. Capacitive electrodes are used as primary sensors to measure the time required by the solid particles to cover a known distance between the electrodes. The capacitive variations of both the electrode sensors are stored in computer synchronously for offline estimation of the velocity of the solid particles. Single glass marble is used as a solid particle to conduct the performance in the lab for its good signal to noise ratio (SNR) and vivid graphs. Matlab R2018a is used as a programming tool to perform the cross-correlation algorithm. The distance between the sensors is adjusted optimally. The results were realistic to ensure the correctness of the system. © 2020 Published under licence by IOP Publishing Ltd. |