CORC  > 江苏大学
Uncapped nanobranch-based CuS clews used as an efficient peroxidase mimic enable the visual detection of hydrogen peroxide and glucose with fast response
Niu, Xiangheng[1]; He, Yanfang[2]; Pan, Jianming[3]; Li, Xin[4]; Qiu, Fengxian[5]; Yan, Yongsheng[6]; Shi, Libo[7]; Zhao, Hongli[8]; Lan, Minbo[9]
刊名ANALYTICA CHIMICA ACTA
2016
卷号947页码:42-49
关键词Uncapped nanobranch-based CuS clews Mimetic peroxidase Colorimetric detection H2O2 Glucose
ISSN号0003-2670
DOIhttp://dx.doi.org/10.1016/j.aca.2016.10.013
URL标识查看原文
收录类别SCI(E) ; EI ; PUBMED
WOS记录号WOS:000388108700006
内容类型期刊论文
URI标识http://www.corc.org.cn/handle/1471x/5364775
专题江苏大学
作者单位[1]Institute of Green Chemistry and Chemical Technology, Jiangsu University, Zhenjiang, 212013, China |School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, China [2]School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, China [3]School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, China [4]School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, China [5]School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, China [6]Institute of Green Chemistry and Chemical Technology, Jiangsu University, Zhenjiang, 212013, China [7]Shanghai Key Laboratory of Functional Materials Chemistry, School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai, 200237, China[8]Shanghai Key Laboratory of Functional Materials Chemistry, School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai, 200237, China[9]Shanghai Key Laboratory of Functional Materials Chemistry, School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai, 200237, China
推荐引用方式
GB/T 7714
Niu, Xiangheng[1],He, Yanfang[2],Pan, Jianming[3],et al. Uncapped nanobranch-based CuS clews used as an efficient peroxidase mimic enable the visual detection of hydrogen peroxide and glucose with fast response[J]. ANALYTICA CHIMICA ACTA,2016,947:42-49.
APA Niu, Xiangheng[1].,He, Yanfang[2].,Pan, Jianming[3].,Li, Xin[4].,Qiu, Fengxian[5].,...&Lan, Minbo[9].(2016).Uncapped nanobranch-based CuS clews used as an efficient peroxidase mimic enable the visual detection of hydrogen peroxide and glucose with fast response.ANALYTICA CHIMICA ACTA,947,42-49.
MLA Niu, Xiangheng[1],et al."Uncapped nanobranch-based CuS clews used as an efficient peroxidase mimic enable the visual detection of hydrogen peroxide and glucose with fast response".ANALYTICA CHIMICA ACTA 947(2016):42-49.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace