Uncapped nanobranch-based CuS clews used as an efficient peroxidase mimic enable the visual detection of hydrogen peroxide and glucose with fast response | |
Niu, Xiangheng[1]; He, Yanfang[2]; Pan, Jianming[3]; Li, Xin[4]; Qiu, Fengxian[5]; Yan, Yongsheng[6]; Shi, Libo[7]; Zhao, Hongli[8]; Lan, Minbo[9] | |
刊名 | ANALYTICA CHIMICA ACTA |
2016 | |
卷号 | 947页码:42-49 |
关键词 | Uncapped nanobranch-based CuS clews Mimetic peroxidase Colorimetric detection H2O2 Glucose |
ISSN号 | 0003-2670 |
DOI | http://dx.doi.org/10.1016/j.aca.2016.10.013 |
URL标识 | 查看原文 |
收录类别 | SCI(E) ; EI ; PUBMED |
WOS记录号 | WOS:000388108700006 |
内容类型 | 期刊论文 |
URI标识 | http://www.corc.org.cn/handle/1471x/5364775 |
专题 | 江苏大学 |
作者单位 | [1]Institute of Green Chemistry and Chemical Technology, Jiangsu University, Zhenjiang, 212013, China |School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, China [2]School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, China [3]School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, China [4]School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, China [5]School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, 212013, China [6]Institute of Green Chemistry and Chemical Technology, Jiangsu University, Zhenjiang, 212013, China [7]Shanghai Key Laboratory of Functional Materials Chemistry, School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai, 200237, China[8]Shanghai Key Laboratory of Functional Materials Chemistry, School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai, 200237, China[9]Shanghai Key Laboratory of Functional Materials Chemistry, School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai, 200237, China |
推荐引用方式 GB/T 7714 | Niu, Xiangheng[1],He, Yanfang[2],Pan, Jianming[3],et al. Uncapped nanobranch-based CuS clews used as an efficient peroxidase mimic enable the visual detection of hydrogen peroxide and glucose with fast response[J]. ANALYTICA CHIMICA ACTA,2016,947:42-49. |
APA | Niu, Xiangheng[1].,He, Yanfang[2].,Pan, Jianming[3].,Li, Xin[4].,Qiu, Fengxian[5].,...&Lan, Minbo[9].(2016).Uncapped nanobranch-based CuS clews used as an efficient peroxidase mimic enable the visual detection of hydrogen peroxide and glucose with fast response.ANALYTICA CHIMICA ACTA,947,42-49. |
MLA | Niu, Xiangheng[1],et al."Uncapped nanobranch-based CuS clews used as an efficient peroxidase mimic enable the visual detection of hydrogen peroxide and glucose with fast response".ANALYTICA CHIMICA ACTA 947(2016):42-49. |