DISTURBANCE EFFECTS CAUSED BY RF POWER LEAKING OUT FROM CAVITIES IN THE PSI RINGCYCLOTRON
D. Goetz ; J. Grillenberger ; M. Humbel ; R. Kan ; M. Schneider ; L. Stingelin ; H. Zhang
2010-09-10
会议日期2010-09-06
会议地点兰州
英文摘要While commissioning the PSI high intensity proton beam facility after the shutdown 2010, direct and indirect phenomena of interaction occurred between the RF power leaking out from the cavities and the electrostatic septa at the injection and extraction region in the Ringcyclotron. As an indirect influence RF fields outside the cavities generate plasma clouds in the peripheral area of magnet poles. Accelerated plasma ions sputtered metallic atoms from the vacuum chamber wall, which then covered the insulator surface with an electrically conductive layer. The septum therefore had to be replaced. Directly, RF power dissipated from the 150 MHz flattop cavity was redirected by a beam stopper in such a way, that a linear correlation between the RF pick up signal monitored at the extraction septum (EEC) and the leakage current across the septum insulator could be observed. As an instant mending action the beam stopper, which is not permanently used, has been removed. The long term attempt to minimize these disturbing effects will be an asymmetrical setting of the hydraulic cavity tuning system and an effective RF grounding of build in components
会议录The 19th International Conference on Cyclotrons and their Applications, CYCLOTRONS'62
资助机构IMP;Chinese Academy of Sciences
语种英语
URL标识查看原文
内容类型会议论文
源URL[http://ir.imp.cas.cn/handle/113462/8623]  
专题近代物理研究所_近代物理研究所知识存储(2010之前)
推荐引用方式
GB/T 7714
D. Goetz,J. Grillenberger,M. Humbel,et al. DISTURBANCE EFFECTS CAUSED BY RF POWER LEAKING OUT FROM CAVITIES IN THE PSI RINGCYCLOTRON[C]. 见:. 兰州. 2010-09-06.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace