CORC  > 北京大学  > 工学院
Color structured light system of chest wall motion measurement for respiratory volume evaluation
Chen, Huijun ; Cheng, Yuan ; Liu, Dongdong ; Zhang, Xiaodong ; Zhang, Jue ; Que, Chengli ; Wang, Guangfa ; Fang, Jing
刊名生物医学光学通讯
2010
关键词biomedical optics optical systems computer vision stereoscopy three dimensions ranging PATTERN
DOI10.1117/1.3368680
英文摘要We present a structured light system to dynamically measure human chest wall motion for respiratory volume estimation. Based on a projection of an encoded color pattern and a few active markers attached to the trunk, respiratory volumes are obtained by evaluating the 3-D topographic changes of the chest wall in an anatomically consistent measuring region during respiration. Three measuring setups are established: a single-sided illuminating-recording setup for standing posture, an inclined single-sided setup for supine posture, and a double-sided setup for standing posture. Results are compared with the pneumotachography and show good agreement in volume estimations [correlation coefficient: R>0.99 (P<0.001) for all setups]. The isovolume tests present small variations of the obtained volume during the isovolume maneuver (standard deviation <0.085 L for all setups). After validation by the isovolume test, an investigation of a patient with pleural effusion using the proposed method shows pulmonary functional differences between the diseased and the contralateral sides of the thorax, and subsequent improvement of this imbalance after drainage. These results demonstrate the proposed optical method is capable of not only whole respiratory volume evaluation with high accuracy, but also regional pulmonary function assessment in different chest wall behaviors, with the advantage of whole-field measurement. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3368680]; http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000278465300044&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=8e1609b174ce4e31116a60747a720701 ; Biochemical Research Methods; Optics; Radiology, Nuclear Medicine & Medical Imaging; SCI(E); EI; PubMed; 6; ARTICLE; 2; 026013; 15
语种英语
内容类型期刊论文
源URL[http://ir.pku.edu.cn/handle/20.500.11897/315708]  
专题工学院
推荐引用方式
GB/T 7714
Chen, Huijun,Cheng, Yuan,Liu, Dongdong,et al. Color structured light system of chest wall motion measurement for respiratory volume evaluation[J]. 生物医学光学通讯,2010.
APA Chen, Huijun.,Cheng, Yuan.,Liu, Dongdong.,Zhang, Xiaodong.,Zhang, Jue.,...&Fang, Jing.(2010).Color structured light system of chest wall motion measurement for respiratory volume evaluation.生物医学光学通讯.
MLA Chen, Huijun,et al."Color structured light system of chest wall motion measurement for respiratory volume evaluation".生物医学光学通讯 (2010).