Color structured light system of chest wall motion measurement for respiratory volume evaluation | |
Chen, Huijun ; Cheng, Yuan ; Liu, Dongdong ; Zhang, Xiaodong ; Zhang, Jue ; Que, Chengli ; Wang, Guangfa ; Fang, Jing | |
刊名 | 生物医学光学通讯 |
2010 | |
关键词 | biomedical optics optical systems computer vision stereoscopy three dimensions ranging PATTERN |
DOI | 10.1117/1.3368680 |
英文摘要 | We present a structured light system to dynamically measure human chest wall motion for respiratory volume estimation. Based on a projection of an encoded color pattern and a few active markers attached to the trunk, respiratory volumes are obtained by evaluating the 3-D topographic changes of the chest wall in an anatomically consistent measuring region during respiration. Three measuring setups are established: a single-sided illuminating-recording setup for standing posture, an inclined single-sided setup for supine posture, and a double-sided setup for standing posture. Results are compared with the pneumotachography and show good agreement in volume estimations [correlation coefficient: R>0.99 (P<0.001) for all setups]. The isovolume tests present small variations of the obtained volume during the isovolume maneuver (standard deviation <0.085 L for all setups). After validation by the isovolume test, an investigation of a patient with pleural effusion using the proposed method shows pulmonary functional differences between the diseased and the contralateral sides of the thorax, and subsequent improvement of this imbalance after drainage. These results demonstrate the proposed optical method is capable of not only whole respiratory volume evaluation with high accuracy, but also regional pulmonary function assessment in different chest wall behaviors, with the advantage of whole-field measurement. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3368680]; http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000278465300044&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=8e1609b174ce4e31116a60747a720701 ; Biochemical Research Methods; Optics; Radiology, Nuclear Medicine & Medical Imaging; SCI(E); EI; PubMed; 6; ARTICLE; 2; 026013; 15 |
语种 | 英语 |
内容类型 | 期刊论文 |
源URL | [http://ir.pku.edu.cn/handle/20.500.11897/315708] |
专题 | 工学院 |
推荐引用方式 GB/T 7714 | Chen, Huijun,Cheng, Yuan,Liu, Dongdong,et al. Color structured light system of chest wall motion measurement for respiratory volume evaluation[J]. 生物医学光学通讯,2010. |
APA | Chen, Huijun.,Cheng, Yuan.,Liu, Dongdong.,Zhang, Xiaodong.,Zhang, Jue.,...&Fang, Jing.(2010).Color structured light system of chest wall motion measurement for respiratory volume evaluation.生物医学光学通讯. |
MLA | Chen, Huijun,et al."Color structured light system of chest wall motion measurement for respiratory volume evaluation".生物医学光学通讯 (2010). |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论