A 50W@170K pulse tube cryocooler used in wide-field survey telescope
Jiang, Zhenhua; Wu, Yinong
2018
卷号 10626
DOI10.1117/12.2304713
英文摘要In this paper, a pulse tube cryocooler used in a wide-field survey telescope is described, this telescope is going to be launched in 2020 in China. And in the telescope, large focal plane array (FPA) detectors working at 188K generate 100W heat which need to be cooled. In order to cool the detectors, three 50W@170K pulse tube cryocoolers are used, with designed life-time of l0 years. To decrease the vibration and electromagnetic interference to the detectors to the minimal limit, two cryogenic loop heat pipes (LHPs) are used to transfer heat from the detectors to the cold tips of the pulse tube cryocoolers. And each cold tip is specified to match the condensers of the LHPs. The cryolooer is driven by a dual-opposed piston compressor with a pair of moving magnet linear motors, one of the motors is also used as the adaptive active vibration suppressor. The cryocooler reaches 16.6% Carnot efficiency at cooling power of 50W@170K with 230Wac input power.
内容类型期刊论文
源URL[http://ir.ihep.ac.cn/handle/311005/282340]  
专题硬X射线调制望远镜卫星
高能物理研究所_粒子天体物理中心
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Jiang, Zhenhua,Wu, Yinong. A 50W@170K pulse tube cryocooler used in wide-field survey telescope[J],2018, 10626.
APA Jiang, Zhenhua,&Wu, Yinong.(2018).A 50W@170K pulse tube cryocooler used in wide-field survey telescope., 10626.
MLA Jiang, Zhenhua,et al."A 50W@170K pulse tube cryocooler used in wide-field survey telescope". 10626(2018).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace