Micro-flame ionization detector with a novel structure for portable gas chromatograph | |
Wang, Jianwei; Wang, Hua; Duan, Chunfeng; Guan, Yafeng | |
刊名 | talanta |
2010-08-15 | |
卷号 | 82期号:3页码:1022-1026 |
关键词 | Micro-flame ionization detector Coaxial gas flow Ionization efficiency Portable gas chromatograph |
通讯作者 | 关亚风 |
产权排序 | 1;1 |
英文摘要 | a micro-flame ionization detector (mu-fid) for portable gas chromatograph (gc) based on conventional mechanical fabrication techniques was developed and evaluated. structure was redesigned and dimensions were optimized for best performance. air is introduced from upper part of the detector, flowing downwards into the burning chamber along a narrow round gap between the collection electrode and the inner wall of the detector body, forming a uniform flow field around the burning jet. the lowest detection limit of the mu-fid was 5 x 10(13) g/s for n-decane, with a linear response range of five orders of magnitude. the consumption of gases is only 10 ml/min for hydrogen, and 120 ml/min for air, that is about 1/3 of the gases required for conventional fids. a comparative study between the mu-fid and commercial fid was also performed that proved the advantages of the mu-fid. the mu-fid is simple in structure, low heating power, and low consumption of gases that not only decrease the cost of running, but also increase the portability of gc for filed applications. (c) 2010 elsevier b.v. all rights reserved. |
WOS标题词 | science & technology ; physical sciences |
类目[WOS] | chemistry, analytical |
研究领域[WOS] | chemistry |
关键词[WOS] | atmospheric-pressure air ; vacuum-outlet gc ; high-speed ; carrier gas ; column ; sensor |
收录类别 | SCI |
原文出处 | false |
语种 | 英语 |
WOS记录号 | WOS:000281177100024 |
公开日期 | 2010-11-30 |
内容类型 | 期刊论文 |
源URL | [http://159.226.238.44/handle/321008/103409] |
专题 | 大连化学物理研究所_中国科学院大连化学物理研究所 |
作者单位 | Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, Dept Instrumentat & Analyt Chem, Dalian 116023, Peoples R China |
推荐引用方式 GB/T 7714 | Wang, Jianwei,Wang, Hua,Duan, Chunfeng,et al. Micro-flame ionization detector with a novel structure for portable gas chromatograph[J]. talanta,2010,82(3):1022-1026. |