Beam-based calibrations of the bpm offset at c-ads injector ii
Chen, Wei-Long1,2; Wang, Zhi-Jun1; Feng, Chi1; Dou, Wei-Ping1; Tao, Yue1,2; Jia, Huan1,2; Wang, Wang-Sheng1; Liu, Shu-Hui1; He, Yuan1
刊名Chinese physics c
2016-07-01
卷号40期号:7页码:4
关键词Ads injector ii Beam commissioning Bpm offset calibration Null comparison method
ISSN号1674-1137
DOI10.1088/1674-1137/40/7/077003
通讯作者He, yuan(hey@impcas.ac.cn)
英文摘要Beam-based bpm offset calibration was carried out for injector ii at the c-ads demonstration facility at the institute of modern physics (imp), chinese academy of science (cas). by using the steering coils integrated in the quadrupoles, the beam orbit can be effectively adjusted and bpm positions recorded at the medium energy beam transport of the injector ii linac. the studies were done with a 2 ma, 2.1 mev proton beam in pulsed mode. during the studies, the "null comparison method" was applied for the calibration. this method is less sensitive to errors compared with the traditional transmission matrix method. in addition, the quadrupole magnet's center can also be calibrated with this method.
WOS研究方向Physics
WOS类目Physics, Nuclear ; Physics, Particles & Fields
语种英语
出版者CHINESE PHYSICAL SOC
WOS记录号WOS:000381730100023
内容类型期刊论文
URI标识http://www.corc.org.cn/handle/1471x/2374395
专题中国科学院大学
通讯作者He, Yuan
作者单位1.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Chen, Wei-Long,Wang, Zhi-Jun,Feng, Chi,et al. Beam-based calibrations of the bpm offset at c-ads injector ii[J]. Chinese physics c,2016,40(7):4.
APA Chen, Wei-Long.,Wang, Zhi-Jun.,Feng, Chi.,Dou, Wei-Ping.,Tao, Yue.,...&He, Yuan.(2016).Beam-based calibrations of the bpm offset at c-ads injector ii.Chinese physics c,40(7),4.
MLA Chen, Wei-Long,et al."Beam-based calibrations of the bpm offset at c-ads injector ii".Chinese physics c 40.7(2016):4.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace