An Approach for Noninvasive Blood Glucose Monitoring Based on Bioimpedance Difference Considering Blood Volume Pulsation
Zedong Nie; Yuhang Liu; Lei Wang; Yang Hao; Jingzhen Li; Tobore Igbe
刊名IEEE Access
2018
文献子类期刊论文
英文摘要Noninvasive blood glucose monitoring (NBGM) provides a promising solution for patients with diabetes with the advantages of painless and continuous monitoring. To better characterize the response of glucose to radio-frequency (RF) signals at low frequencies, the conductivity and relative permittivity of aqueous solutions with different glucose concentrations were obtained by the use of an impedance analyzer in the frequency range of 1 kHz to 1 MHz. Furthermore, considering the blood volume pulsation in cardiac cycle, a new approach based on measuring bioimpedance was presented for NBGM in this paper. For this purpose, an inhomogeneous arm model, which consists of three tissue layers (i.e., blood, blood vessel, and other relevant tissues), was proposed to validate the aforementioned approach. Furthermore, the measurements were carried out by means of in vitro experiment and in vivo studies, respectively. The results showed that as the glucose concentration increased, the conductivity of aqueous solutions decreased when the frequency of RF signal was below 1 MHz. However, the relative permittivity was almost insensitive to glucose concentration. The simulation result of the arm model showed that as the glucose concentration increased, the bioimpedance difference of blood volume decreased. This was supported by both in vitro and in vivo experiments. We therefore suggest that the proposed approach for NBGM has potentials in practical applications.
URL标识查看原文
语种英语
内容类型期刊论文
源URL[http://ir.siat.ac.cn:8080/handle/172644/14257]  
专题深圳先进技术研究院_医工所
推荐引用方式
GB/T 7714
Zedong Nie,Yuhang Liu,Lei Wang,et al. An Approach for Noninvasive Blood Glucose Monitoring Based on Bioimpedance Difference Considering Blood Volume Pulsation[J]. IEEE Access,2018.
APA Zedong Nie,Yuhang Liu,Lei Wang,Yang Hao,Jingzhen Li,&Tobore Igbe.(2018).An Approach for Noninvasive Blood Glucose Monitoring Based on Bioimpedance Difference Considering Blood Volume Pulsation.IEEE Access.
MLA Zedong Nie,et al."An Approach for Noninvasive Blood Glucose Monitoring Based on Bioimpedance Difference Considering Blood Volume Pulsation".IEEE Access (2018).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace