CORC  > 高能物理研究所
General rigid motion correction for computed tomography imaging based on locally linear embedding
Chen, Mianyi1,2; He, Peng1,2; Feng, Peng1,2; Liu, Baodong3,4; Yang, Qingsong5; Wei, Biao1,2; Wang, Ge5
刊名Optical engineering
2018-02-01
卷号57期号:2页码:15
关键词Rigid patient motion Cone-beam geometry Locally linear embedding
ISSN号0091-3286
DOI10.1117/1.oe.57.2.023102
通讯作者He, peng(penghe@cqu.edu.cn) ; Wang, ge(wangg6@rpi.edu)
英文摘要The patient motion can damage the quality of computed tomography images, which are typically acquired in cone-beam geometry. the rigid patient motion is characterized by six geometric parameters and are more challenging to correct than in fan-beam geometry. we extend our previous rigid patient motion correction method based on the principle of locally linear embedding (lle) from fan-beam to cone-beam geometry and accelerate the computational procedure with the graphics processing unit (gpu)-based all scale tomographic reconstruction antwerp toolbox. the major merit of our method is that we need neither fiducial markers nor motion-tracking devices. the numerical and experimental studies show that the lle-based patient motion correction is capable of calibrating the six parameters of the patient motion simultaneously, reducing patient motion artifacts significantly. (c) 2018 society of photo-optical instrumentation engineers (spie)
WOS关键词FAN-BEAM CT ; ITERATIVE RECONSTRUCTION ; ARTIFACT REDUCTION ; ASTRA TOOLBOX ; HEAD MOTION ; COMPENSATION ; ALGORITHM ; SART ; ART
WOS研究方向Optics
WOS类目Optics
语种英语
出版者SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS
WOS记录号WOS:000427030700011
内容类型期刊论文
URI标识http://www.corc.org.cn/handle/1471x/2178059
专题高能物理研究所
通讯作者He, Peng; Wang, Ge
作者单位1.Chongqing Univ, Key Lab Optoelect Technol & Syst, Minist Educ, Chongqing, Peoples R China
2.Chongqing Univ, Collaborat Innovat Ctr Brain Sci, Chongqing, Peoples R China
3.Chinese Acad Sci, Beijing Engn Res Ctr Radiog Tech & Equipment, Inst High Energy Phys, Beijing, Peoples R China
4.Univ Chinese Acad Sci, Sch Nucl Sci & Technol, Beijing, Peoples R China
5.Rensselaer Polytech Inst, Dept Biomed Engn, Troy, NY 12180 USA
推荐引用方式
GB/T 7714
Chen, Mianyi,He, Peng,Feng, Peng,et al. General rigid motion correction for computed tomography imaging based on locally linear embedding[J]. Optical engineering,2018,57(2):15.
APA Chen, Mianyi.,He, Peng.,Feng, Peng.,Liu, Baodong.,Yang, Qingsong.,...&Wang, Ge.(2018).General rigid motion correction for computed tomography imaging based on locally linear embedding.Optical engineering,57(2),15.
MLA Chen, Mianyi,et al."General rigid motion correction for computed tomography imaging based on locally linear embedding".Optical engineering 57.2(2018):15.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace