Solution-based calibration strategy for laser ablation-inductively coupled plasma-mass spectrometry using desolvating nebulizer system
Zhang, Guoxia; Li, Qing; Zhu, Yan; Wang, Zheng
刊名SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY
2018
卷号145页码:51
关键词LA-ICP-MS Solution-based Desolvating nebulizer system
ISSN号0584-8547
DOI10.1016/j.sab.2018.04.004
英文摘要An additional quantification strategy using a desolvating nebulizer system (DNS) for solution-based calibration was developed. For quantitative analysis, laser ablation (LA) and DNS-generated aerosols were coupled using a "Y" connector and introduced into the inductively coupled plasma (ICP). These aerosols were also observed by scanning electron microscopy following collection on a silicon chip. Internal standards (Ag-108, Cu-64, Y-89) were used to correct for the different aerosol transport efficiencies between the DNS and LA. The correlation coefficients of the calibration curves for all elements ranged from 0.9986 to 0.9999 Standard reference materials (NIST 610-616 and GBW08407-08411) were used to demonstrate the accuracy and precision of the method. The results were in good agreement with certified values, and the relative standard deviation (RSD) of most elements was <3%. The limits of detection (LODs) for Cr-50, Mn-55, Co-59, Ni-60, Zn-66, Y-89,Cd-110, La-139, Ce-140, Nd-146, Sm-147, Gd-157, Dy-163, Er-166, and Pb-208 were 23,3,3,19,31,4,12,0.4,0.9,0.1,0.2,2, 0.3,0.4, and 21 ng/g, respectively, which were significantly better than those obtained by other methods. Further, this approach was applied for the analysis of multiple elements in biological tissues, and the results were in good agreement with those obtained using solution-based inductively coupled plasma-mass spectrometry (ICP-MS). (C) 2018 Elsevier B.V. All rights reserved.
学科主题Spectroscopy
出版者PERGAMON-ELSEVIER SCIENCE LTD
WOS记录号WOS:000436911100007
资助机构The financial support of the Development and Innovation of Instrument Functions, CAS (No. Y27YQ3120G), the Key Program of Creative Funding of SICCAS (No. Y37ZC4140G) and Shanghai technical platform for testing and characterization on inorganic materials (No. 14DZ2292900) are gratefully acknowledged. ; The financial support of the Development and Innovation of Instrument Functions, CAS (No. Y27YQ3120G), the Key Program of Creative Funding of SICCAS (No. Y37ZC4140G) and Shanghai technical platform for testing and characterization on inorganic materials (No. 14DZ2292900) are gratefully acknowledged.
内容类型期刊论文
源URL[http://ir.sic.ac.cn/handle/331005/24839]  
专题中国科学院上海硅酸盐研究所
作者单位Chinese Acad Sci, Shanghai Inst Ceram, Shanghai 200050, Peoples R China
推荐引用方式
GB/T 7714
Zhang, Guoxia,Li, Qing,Zhu, Yan,et al. Solution-based calibration strategy for laser ablation-inductively coupled plasma-mass spectrometry using desolvating nebulizer system[J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY,2018,145:51, 57.
APA Zhang, Guoxia,Li, Qing,Zhu, Yan,&Wang, Zheng.(2018).Solution-based calibration strategy for laser ablation-inductively coupled plasma-mass spectrometry using desolvating nebulizer system.SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY,145,51.
MLA Zhang, Guoxia,et al."Solution-based calibration strategy for laser ablation-inductively coupled plasma-mass spectrometry using desolvating nebulizer system".SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY 145(2018):51.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace