CORC  > 厦门大学  > 2010年第16卷
医用钛表面TiO_2纳米管/HA复合膜层于Tyrode’s生理溶液中电化学腐蚀行为; Electrochemical Corrosion Behavior of TiO_2/HA Composite Coating on Medical Titanium in Tyrode's Physiological Solution
孔丽丽 ; 林龙翔 ; 胡融刚 ; 张帆 ; 林昌健 ; KONG Li-li ; LIN Long-xiang ; HU Rong-gang ; ZHANG Fan ; LIN Chang-jian
刊名http://electrochem.xmu.edu.cn/CN/abstract/abstract8456.shtml
2010-02-28
关键词医用植入体 生理腐蚀 TiO2纳米管阵列 羟基磷灰石 电沉积 medical implant materials physiological corrosion titanium TiO2 nanotube arrays electrodepostion
英文摘要钛及其合金具有良好的力学性能和生物相容性,被广泛地用作医用人工植入体.然而,钛植入体在人体内的生理环境中必然发生腐蚀,金属离子的溶出和积累可产生毒副作用.本文应用电化学方法对医用钛金属作表面改性,提高其生物活性,应用Tafel极化曲线和电化学阻抗(EIS)研究其耐蚀性能及腐蚀电化学行为.结果表明,在钛基TiO2纳米管阵列膜层上沉积构筑HA涂层之后,由于表面阻挡层的强化,TiO2涂层在Tyrode’s生理溶液中的耐蚀性有所提高.; Titanium and its alloys have been widely used as medical implant materials because of their good mechanical properties and biocompatibility.However,the physiological corrosion of metal will release metal ions,resulting in toxic and side effects.In this paper,in order to improve the corrosion resistance of titanium,and to enhance its bioactivity and osseointegration,the surface modification of titamum were performed.Using eletrochemical methods Tafel polarization and electrochemical impedance spectroscopy(EIS) were applied to study the electrochemical corrosion behavior of TiO2 /HA composite coating.It is indicated that the corrosion resistance of the prepared TiO2 /Ti material in Tyrode's physiological solution is improved because of the enhanced surface barrier.; 作者联系地址:厦门大学固体表面物理化学国家重点实验室化学化工学院化学系;; Author's Address: State Key Laboratory for Physical Chemistry of Solid Surfaces,and Department of Chemistry,College of Chemistry and Chemical Engineering,Xiamen University,Xiamen 361005,Fujian,China
语种中文
出版者厦门大学《电化学》编辑部
内容类型期刊论文
源URL[http://dspace.xmu.edu.cn/handle/2288/58370]  
专题2010年第16卷
推荐引用方式
GB/T 7714
孔丽丽,林龙翔,胡融刚,等. 医用钛表面TiO_2纳米管/HA复合膜层于Tyrode’s生理溶液中电化学腐蚀行为, Electrochemical Corrosion Behavior of TiO_2/HA Composite Coating on Medical Titanium in Tyrode's Physiological Solution[J]. http://electrochem.xmu.edu.cn/CN/abstract/abstract8456.shtml,2010.
APA 孔丽丽.,林龙翔.,胡融刚.,张帆.,林昌健.,...&LIN Chang-jian.(2010).医用钛表面TiO_2纳米管/HA复合膜层于Tyrode’s生理溶液中电化学腐蚀行为.http://electrochem.xmu.edu.cn/CN/abstract/abstract8456.shtml.
MLA 孔丽丽,et al."医用钛表面TiO_2纳米管/HA复合膜层于Tyrode’s生理溶液中电化学腐蚀行为".http://electrochem.xmu.edu.cn/CN/abstract/abstract8456.shtml (2010).