3-D simulation of remote field eddy current detection for stress corrosion cracks in pipeline | |
Wu, De Hui ; Zhang, Zhong Yuan ; Liu, Zhen Liang ; Xia, Xiao Hao ; Wu DH(吴德会) | |
2013 | |
关键词 | Computer simulation Cracks Eddy current testing Eddy currents Electronics engineering Finite element method Information technology Signal detection Stress corrosion cracking |
英文摘要 | Conference Name:2nd International Conference on Opto-Electronics Engineering and Materials Research, OEMR 2013. Conference Address: Zhengzhou, Henan, China. Time:October 19, 2013 - October 20, 2013.; Computer Science and Electronic Technology; Trans tech publications inc.; National Cheng Kung University; Three-dimensional (3-D) finite element simulation models are conducted to simulate the in-service inspection of the axial stress corrosion cracking (SCC) in ferromagnetic pipeline using remote field eddy current (RFEC) probes. In this paper, a typical remote field eddy current probe which is internal to and coaxial with the pipe is firstly introduced. Then a 3-D finite element simulation model is established in ANSYS to analyze the detection of RFEC technology. Finally the RFEC signals are observed when changing the geometric parameters, and the definite influences of crack size on the amplitude and phase lag of REFC signals are evaluated. The results of the investigations are beneficial to the detection and sizing of SCC in pipelines. ? (2013) Trans Tech Publications, Switzerland. |
语种 | 英语 |
出处 | http://dx.doi.org/10.4028/www.scientific.net/AMR.760-762.1154 |
出版者 | Trans Tech Publications Ltd |
内容类型 | 其他 |
源URL | [http://dspace.xmu.edu.cn/handle/2288/86183] ![]() |
专题 | 物理技术-会议论文 |
推荐引用方式 GB/T 7714 | Wu, De Hui,Zhang, Zhong Yuan,Liu, Zhen Liang,et al. 3-D simulation of remote field eddy current detection for stress corrosion cracks in pipeline. 2013-01-01. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论