Fused deposition modelling of an auricle framework for microtia reconstruction based on CT images | |
Zeng, Wen ; Lin, Feng ; Shi, Tingchun ; Zhang, Renji ; Nian, Yongyan ; Ruan, Jie ; Zhou, Tianrui | |
2010-05-10 ; 2010-05-10 | |
关键词 | Plastic surgery Image scanners Modelling Ears Thermoplastic polymers Engineering, Mechanical Materials Science, Multidisciplinary |
中文摘要 | Purpose - In plastic reconstruction surgeries, total auricular reconstruction for microtia is a real challenge. Presently, autogenous costal cartilage and MEDPOR are the chosen materials but none can satisfy the requirements of orthopaedic operation. The purpose of this paper is to examine how to fabricate an ear scaffold with a good shape. Design/methodology/approach - A new approach to form the auricle framework is described. CT scan data of the patient's contralateral "good ear" are used to generate a 3D reconstruction model of the new ear. This model is then imported into rapid prototyping (RP) software to slice. The sliced data drive the fused deposition modeling (FDM) machine to build the ear framework layer by layer. Based on the actual shape of the computer model, FDM technology produces a real feel ear framework to match the size of the opposite good ear. Findings - An artificial human ear was built using FDM technology based on CT images. The auricular framework with polyurethane was a porous structure with good flexibility and biocompatibility. After implanting into the mouse, a real life human ear appeared on the back of the mouse. The experiment indicated that this method provided an efficient way to macrotia reconstruction. Originality/value - The freeform fabrication technique combined with CT image reconstruction could provide an efficient way to produce a porous structure and solve the framework carving problem in microtia reconstruction. |
语种 | 英语 ; 英语 |
出版者 | EMERALD GROUP PUBLISHING LIMITED ; BINGLEY ; HOWARD HOUSE, WAGON LANE, BINGLEY BD16 1WA, W YORKSHIRE, ENGLAND |
内容类型 | 期刊论文 |
源URL | [http://hdl.handle.net/123456789/24047] |
专题 | 清华大学 |
推荐引用方式 GB/T 7714 | Zeng, Wen,Lin, Feng,Shi, Tingchun,et al. Fused deposition modelling of an auricle framework for microtia reconstruction based on CT images[J],2010, 2010. |
APA | Zeng, Wen.,Lin, Feng.,Shi, Tingchun.,Zhang, Renji.,Nian, Yongyan.,...&Zhou, Tianrui.(2010).Fused deposition modelling of an auricle framework for microtia reconstruction based on CT images.. |
MLA | Zeng, Wen,et al."Fused deposition modelling of an auricle framework for microtia reconstruction based on CT images".(2010). |