Design and Implementation of Embedded Telemetry System for Amperometric Detection | |
Li Xiao-Gang1; Guo Bin-Qian1; Qin Tai-Chun1; Hao Jie2; Yu Ping2; Mao Lan-Qun2 | |
刊名 | CHINESE JOURNAL OF ANALYTICAL CHEMISTRY |
2016-09-01 | |
卷号 | 44期号:9页码:1465-1470 |
关键词 | Telemetry system Miniaturization Electrochemistry Amperometric Ascorbic acid |
英文摘要 | A new micro embedded telemetry system was developed for the amperometric sensing detection. Its output voltage range was +/- 0. 5 V and resolution was < 1 mV. The current acquisition range was +/- 1 mu A and the minimum resolution was 0. 2 nA. This telemetry system was designed based on microprocessor ADuCM360, including a potentiostat, a current detection module and a radio module. And the size was only 24 mm. 13 mm. 11 mm. The computer software written in LabVIEW language was used for data storage and display. In order to verify the accuracy and reliability of this system, an electrical performance test was performed. The current response for ascorbic acid with different concentration was recorded by using the telemetry system. The potential of working electrode was set as 30 mV, and the current response of ascorbic acid electrode had a good linear relationship with its concentration within the concentration range of 50-300 mu mol/L. Linear equation was I(nA) = 2. 98C(AA) (mu mol/L) - 137. 39, and linear correlation coefficient R-2 = 0. 984. Moreover, the applicability of the instrument in the study for living animals was explored by using the cerebral ischemia as model. |
收录类别 | SCI |
语种 | 英语 |
内容类型 | 期刊论文 |
源URL | [http://ir.iccas.ac.cn/handle/121111/36436] |
专题 | 化学研究所_活体分析化学实验室 |
作者单位 | 1.Beihang Univ, Sch Reliabil & Syst Engn, Beijing 100191, Peoples R China 2.Chinese Acad Sci, Inst Chem, Key Lab Analyt Chem Living Biosyst, Beijing 100190, Peoples R China |
推荐引用方式 GB/T 7714 | Li Xiao-Gang,Guo Bin-Qian,Qin Tai-Chun,et al. Design and Implementation of Embedded Telemetry System for Amperometric Detection[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2016,44(9):1465-1470. |
APA | Li Xiao-Gang,Guo Bin-Qian,Qin Tai-Chun,Hao Jie,Yu Ping,&Mao Lan-Qun.(2016).Design and Implementation of Embedded Telemetry System for Amperometric Detection.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,44(9),1465-1470. |
MLA | Li Xiao-Gang,et al."Design and Implementation of Embedded Telemetry System for Amperometric Detection".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 44.9(2016):1465-1470. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论