Comparison between conventional and golden ratio based radial trajectories: an eddy currents study
Jie Yang; Yanchun Zhu; Shuo Li; Nan Fu; Shaode Yu; Rongmao Li; Yaoqin Xie
刊名BMC Medical Imaging
2016
英文摘要Aims:Golden ratio based k-space trajectories are widely used in dynamic MRI since it provides approximate uniform k-space distribution. However, rapidly switching gradient induces eddy currents, generating artifacts in image. The golden ratio (GR) based radial strategy was compared with conventional radial strategy on 0.7T open superconducting MRI system.Materials and methods:In conventional radial strategy, a constant angle increment Φuniform = 180°/P between neighboring profiles. In GR based radial strategy, the azimuthal spacing is ΦGR = 180°/1.618 = 111.2°. First, a simulation was carried out to the comparison between ideal and net gradient of Shepp-Logan phantom with two radial strategies respectively. Second, a pure water phantom was sampled by Cartesian, conventional and GR based radial trajectory on the 0.7T open superconducting MRI system. Three orthogonal planes were acquired. SNR was compared between these three sampling trajectories, and images from Cartesian trajectory were used as reference.Results:Result of simulation has illustrated that the impact of eddy currents on the ideal gradient with GR based radial strategy is more apparent. The result of a pure phantom shows that SNR values of both radial strategies (conventional: 40.76 GR:16.11) are far smaller than Cartesian strategy (145.15).Conclusions:Eddy currents artifacts are more serious in GR based radial trajectory. Rapid switching gradient in GR based radial strategy induces more eddy currents than conventional radial strategy, which may limit the application of GR based trajectories especially in high magnet filed system.
收录类别其他
原文出处https://bmcmedimaging.biomedcentral.com/articles/10.1186/s12880-016-0164-6
语种英语
内容类型期刊论文
源URL[http://ir.siat.ac.cn:8080/handle/172644/10423]  
专题深圳先进技术研究院_医工所
作者单位BMC Medical Imaging
推荐引用方式
GB/T 7714
Jie Yang,Yanchun Zhu,Shuo Li,et al. Comparison between conventional and golden ratio based radial trajectories: an eddy currents study[J]. BMC Medical Imaging,2016.
APA Jie Yang.,Yanchun Zhu.,Shuo Li.,Nan Fu.,Shaode Yu.,...&Yaoqin Xie.(2016).Comparison between conventional and golden ratio based radial trajectories: an eddy currents study.BMC Medical Imaging.
MLA Jie Yang,et al."Comparison between conventional and golden ratio based radial trajectories: an eddy currents study".BMC Medical Imaging (2016).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace