Effect of Suture Density on the Dynamic Behavior of the Bioprosthetic Heart Valve: A Numerical Simulation Study
Xin Ye; Linan Zhang; Zaobing Xu; Zengtao Hou; Xueling Bai; Peng Shang
刊名Health Information Science
2014
英文摘要This paper constructs the bioprosthetic valve leaflets’ parametric model using computer aided design. A series of accurate parameters of the bioproshtetic heart valve, such as radius of the sutural ring, height of the supporting stent and inclination of the supporting stent are determined. Numerical simulation is used to determine the effect of different shape designs and suture density on the mechanical performance of the bioprosthetic valve leaflet. The dynamic behavior of the valve during diastolic phase is analyzed. The finite element analysis results show that the stress distribution of the ellipsoidal leaflet valve is good. The ellipsoidal leaflet valve has the following advantages over the cylindrical leaflet valve: lower peak von Mises-stress, smaller stress concentration area and relatively uniform stress distribution. The suture density also has a significant effect on the dynamic behavior of the valve as it can act to reduce the pressure and improve the stress distribution. It was found that the influence of suture density in the stress of the leaflet differs on the basis of different geometries considered in the model. The degree of influence of the suture density in the bioprosthetic heart valve may also be dependent on the geometries of the valves. This indicates the need to account for the attachment edge, when manufacturing such bioproshetic heart valves for long term durability. Further research is required to assess the effect of suture density on the bioprosthetic heart valve models.
收录类别EI
原文出处http://download.springer.com/static/pdf/742/chp%253A10.1007%252F978-3-319-06269-3_4.pdf?originUrl=http%3A%2F%2Flink.springer.com%2Fchapter%2F10.1007%2F978-3-319-06269-3_4&token2=exp=1433669209~acl=%2Fstatic%2Fpdf%2F742%2Fchp%25253A10.1007%25252F978-3-319-06269-3_4.pdf%3ForiginUrl%3Dhttp%253A%252F%252Flink.springer.com%252Fchapter%252F10.1007%252F978-3-319-06269-3_4*~hmac=f1c1ea0c3c689f989ddd83c73b760e864a56858316f540547e690370e4fd0aae
语种英语
内容类型期刊论文
源URL[http://ir.siat.ac.cn:8080/handle/172644/5840]  
专题深圳先进技术研究院_医工所
作者单位Health Information Science
推荐引用方式
GB/T 7714
Xin Ye,Linan Zhang,Zaobing Xu,et al. Effect of Suture Density on the Dynamic Behavior of the Bioprosthetic Heart Valve: A Numerical Simulation Study[J]. Health Information Science,2014.
APA Xin Ye,Linan Zhang,Zaobing Xu,Zengtao Hou,Xueling Bai,&Peng Shang.(2014).Effect of Suture Density on the Dynamic Behavior of the Bioprosthetic Heart Valve: A Numerical Simulation Study.Health Information Science.
MLA Xin Ye,et al."Effect of Suture Density on the Dynamic Behavior of the Bioprosthetic Heart Valve: A Numerical Simulation Study".Health Information Science (2014).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace