Restoration of longitudinal growth by bioengineered cartilage pellet in physeal injury is not affected by low intensity pulsed ultrasound
Simon Kwoon-Ho Chow; Kwong-Man Lee; Ling Qin; Kwok-Sui Leung; andWing-Hoi Cheung
刊名JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS
2011
卷号99期号:1页码:36-44
英文摘要Physeal fracture is a common pediatric fracture that would result in premature physeal closure in long bones, and there is currently no gold standard for its management. In this study, we investigated the application of a Bioengineered Cartilage Pellet (BCP) in repairing a rabbit physeal fracture model, and the possible effects of Low Intensity Pulsed Ultrasound (LIPUS) treatment. Rabbits with physeal fracture created were assigned to the NC group (no BCP, no LIPUS), GC group (BCP, no LIPUS), and GT group (BCP and LIPUS). Femoral lengths and cartilage area were assessed at 4, 8, and 16 weeks post-defect. After transplantation, the BCP showed continuous growth in the host and demonstrated resemblance to a natural growth plate. The GC group showed 34.1, 32.1, and 41.1% advantage in lengthening over the NC group and the GT group showed 51.1, 41.6, and 26.9% improved lengthening than the NC group, at 4 (p = 0.203), 8 (p = 0.543) and 16 weeks (p = 0.049), respectively. Cartilage area was shown to be significantly higher in GC and GT group compared to NC group (p < 0.05). No significant difference was found between GC and GT group. Femoral longitudinal growth was shown to be improved by the BCP, however no additional enhancement effect was shown to be provided by LIPUS.
收录类别SCI
原文出处http://onlinelibrary.wiley.com/doi/10.1002/jbm.b.31869/full
语种英语
内容类型期刊论文
源URL[http://ir.siat.ac.cn:8080/handle/172644/3487]  
专题深圳先进技术研究院_医工所
作者单位JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS
推荐引用方式
GB/T 7714
Simon Kwoon-Ho Chow,Kwong-Man Lee,Ling Qin,et al. Restoration of longitudinal growth by bioengineered cartilage pellet in physeal injury is not affected by low intensity pulsed ultrasound[J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS,2011,99(1):36-44.
APA Simon Kwoon-Ho Chow,Kwong-Man Lee,Ling Qin,Kwok-Sui Leung,&andWing-Hoi Cheung.(2011).Restoration of longitudinal growth by bioengineered cartilage pellet in physeal injury is not affected by low intensity pulsed ultrasound.JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS,99(1),36-44.
MLA Simon Kwoon-Ho Chow,et al."Restoration of longitudinal growth by bioengineered cartilage pellet in physeal injury is not affected by low intensity pulsed ultrasound".JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS 99.1(2011):36-44.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace