Quantitative analysis of proteins via sulfur determination by HPLC coupled to isotope dilution ICPMS with a hexapole collision cell | |
Wang M(王萌); Feng WY(丰伟悦); Li B(李柏); Wang B(汪冰); Zhu MT(朱墨桃); Wang Y(王云); Yuan H(袁慧); Zhao YL(赵宇亮); Chai ZF(柴之芳); Wang, M | |
刊名 | ANALYTICAL CHEMISTRY |
2007 | |
卷号 | 79期号:23页码:9128-9134 |
通讯作者 | Chinese Acad Sci, Inst High Energy Phys, Lab Bio Environm Effects Nanomat & Nanosafely, Key Lab Nucl Anal Tech, Beijing, Peoples R China ; Chinese Acad Sci, Grad Sch, Beijing, Peoples R China ; Shanghai Jiao Tong Univ, Shanghai, Peoples R China |
英文摘要 | Quantitative analysis of proteins is an essential part and also constitutes a major challenge in modem proteomics. Quantification of proteins by inductively coupled plasma mass spectrometry (ICPMS) offers an alternative method for quantitative proteomics. In this study, we developed a method of absolute quantification of proteins via sulfur by size exclusion chromatography (SEC) coupled to ICPMS with a collision cell (ICP-CC-MS) and postcolumn isotope dilution. Bovine serum albumin (BSA), superoxide dismutase (SOD), and metallothionein-II (MT-II) served as model proteins. Enriched (34)S, (65)Cu, and (67)Zn isotopic solutions were continuously mixed with the eluate from the SEC. Oxygen was added as a reactive gas into the collision cell where sulfur reacts with oxygen to form sulfur-oxygen ion, the ratio of (32)S(16)O(+)/(34)S(16)O(+) thus representing (32)S(+)/(34)S(+). The absolute quantity of proteins could be calculated by the isotopic dilution equation and the content of sulfur in the proteins. The detection limits for BSA, SOD, and MT-II are 8, 31, and 15 pmol, respectively. The relative standard deviations for the proteins are less than 3%. The ratios of S/Cu and S/Zn in the proteins were also determined. The quantitative method was validated by comparing with gravimetric results. |
学科主题 | Chemistry |
类目[WOS] | Chemistry, Analytical |
研究领域[WOS] | Chemistry |
原文出处 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000251311900045 |
内容类型 | 期刊论文 |
源URL | [http://ir.ihep.ac.cn/handle/311005/240156] |
专题 | 高能物理研究所_院士 高能物理研究所_实验物理中心 高能物理研究所_加速器中心 高能物理研究所_多学科研究中心 |
作者单位 | 中国科学院高能物理研究所 |
推荐引用方式 GB/T 7714 | Wang M,Feng WY,Li B,et al. Quantitative analysis of proteins via sulfur determination by HPLC coupled to isotope dilution ICPMS with a hexapole collision cell[J]. ANALYTICAL CHEMISTRY,2007,79(23):9128-9134. |
APA | 王萌.,丰伟悦.,李柏.,汪冰.,朱墨桃.,...&Chai, ZF.(2007).Quantitative analysis of proteins via sulfur determination by HPLC coupled to isotope dilution ICPMS with a hexapole collision cell.ANALYTICAL CHEMISTRY,79(23),9128-9134. |
MLA | 王萌,et al."Quantitative analysis of proteins via sulfur determination by HPLC coupled to isotope dilution ICPMS with a hexapole collision cell".ANALYTICAL CHEMISTRY 79.23(2007):9128-9134. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论